Absorbed dose and dose equivalent in water and silicon computed from shielded spectra, and the reference doses used for comparison.

Quantities

Method

Method
Charged-particle fluence times stopping power, with the ICRP 60 quality factor; neutrons and photons as the mean dose in a water sphere of 15 cm radius.
Checked against
MSL/RAD in cruise and the DOSIS dosimeters on the ISS.
Expect
A factor 2 to 3. The mean quality factor is low because target fragments made inside the body are left out.

Starting from the internal spectra (shielding):

The charged and neutral terms therefore refer to different targets, a point and a body-sized sphere; both are reported.

Dose panel

The dose panel of the 3D explorer evaluates four targets:

TargetDefinition
Extravehicular crewDose equivalent at 5 g/cm² depth (blood-forming organs) behind a 0.3 g/cm² suit
Intravehicular crewAs above, behind 1, 3, 10 or 30 g/cm², or the ISS interior distribution
Silicon, exposedAbsorbed dose in silicon behind a 0.3 g/cm² lid
Silicon, shieldedAbsorbed dose in silicon behind the selected wall

Intermediate thicknesses are interpolated in log thickness. Silicon dose is the water dose times the stopping-power ratio: 0.80 for ions, 0.84 for electrons and positrons, 0.90 for photons and about 0.05 for neutrons, silicon containing no hydrogen. Each target is shown by particle type, integrated over the selected duration, and placed on a logarithmic scale of reference doses.

Reference doses

Used forSourceBasis
Banana ≈ 0.1 µSv committed dose (K-40)this project
Conventional ballpark used in radiation-protection outreach, not a measurement
rule of thumb
Chest X-ray (PA) 0.02 mSv; chest CT 6.1 mSvMettler et al. (2008)review of measurements
NY–LA round-trip flight 0.03 mSvBardo & Brown (2008)
Table 2
review
US natural background 3.1 mSv/yrNCRP Report No. 160 (2009)standard
Deep-space GCR inside MSL: 1.84 mSv/dayZeitlin et al. (2013)primary measurement
US occupational limit 50 mSv/yr TEDE10 CFR 20.1201regulation
NASA career limit 600 mSv effective doseNASA-STD-3001 Vol. 1 Rev. B (2022)
Vol. 1 Rev. B (2022)
standard
ARS above ~0.7 Gy acute; LD50/60 ~2.5–5 Gy without treatmentCDC, Acute Radiation Syndrome: Information for Cliniciansguidance
Total-ionizing-dose hardness levels M 3 krad(Si) … H 1 Mrad(Si)MIL-PRF-38535
RHA designators
standard
Si/water dose ratios (0.80 ions, 0.84 e±, 0.90 γ, ~0.05 n)this project
Bethe stopping-power ratio (Z/A and I = 75 vs 173 eV); photon μ_en/ρ ratio near 1 MeV; Si neutron kerma vs tissue (order of magnitude)
derived

Comparison with measurements

Expected accuracy of the dose estimates is a factor of 2 to 3 (validation).

Radial dependence of quiet-time dose

Steady solar output (visible light and the 1 keV solar wind) is stopped within the first micrometers of a suit or hull. Quiet-time internal dose is therefore due to galactic cosmic rays, whose intensity increases slowly with heliocentric distance. In the model, extravehicular dose equivalent is about 1.5 mSv/day between 0.1 and 1 AU and about 2.2 mSv/day at 15 AU.

During solar particle events the dependence reverses: inside 1 AU the peak rate scales as r⁻²·⁷, so at 0.11 AU the peak of the October 2003 event is about 400 times its 1 AU value. The dose panel identifies the applicable regime.

Dose against depth (Python engine)

Method
SHIELDOSE-2 for electrons, bremsstrahlung and protons.
Checked against
Nothing independent yet.
Expect
No heavy ions or neutrons, so deep-shielding cosmic-ray dose is underestimated.

The Python engine also provides SHIELDOSE-2 Seltzer (1994) for dose behind aluminum from trapped particles and solar protons, as a function of depth in slab and solid-sphere geometries.

Page status: draft, updated 2026-11-16. radiation.space 0.1.0 (e1a50c428882).
These are estimates for learning and early trade studies. They are not a substitute for a mission radiation analysis, and nothing here is medical advice.