Dose
Absorbed dose and dose equivalent in water and silicon computed from shielded spectra, and the reference doses used for comparison.
Quantities
- Absorbed dose: energy deposited per unit mass, in gray (Gy). In silicon often given in rad (1 Gy = 100 rad).
- Dose equivalent: absorbed dose weighted by the quality factor Q, a function of linear energy transfer, in sievert (Sv).
- Total ionizing dose: cumulative absorbed dose in silicon, the measure of electronic degradation.
Method
- Method
- Charged-particle fluence times stopping power, with the ICRP 60 quality factor; neutrons and photons as the mean dose in a water sphere of 15 cm radius.
- Checked against
- MSL/RAD in cruise and the DOSIS dosimeters on the ISS.
- Expect
- A factor 2 to 3. The mean quality factor is low because target fragments made inside the body are left out.
Starting from the internal spectra (shielding):
- Charged particles: point dose, the integral over energy of fluence times stopping power. Proton stopping powers are from Geant4; heavier nuclei use the proton value scaled by the Barkas effective charge Barkas (1963); electrons and positrons use the ICRU Report 37 collision stopping power ICRU Report 37 (1984) Sternheimer et al. (1984).
- Quality factor: Q(L) from ICRP Publication 60 ICRP Publication 60 (1991), evaluated at the linear energy transfer in water.
- Neutrons and photons: mean dose in a water sphere of 15 cm radius per unit fluence, computed with Geant4.
The charged and neutral terms therefore refer to different targets, a point and a body-sized sphere; both are reported.
Dose panel
The dose panel of the 3D explorer evaluates four targets:
| Target | Definition |
|---|---|
| Extravehicular crew | Dose equivalent at 5 g/cm² depth (blood-forming organs) behind a 0.3 g/cm² suit |
| Intravehicular crew | As above, behind 1, 3, 10 or 30 g/cm², or the ISS interior distribution |
| Silicon, exposed | Absorbed dose in silicon behind a 0.3 g/cm² lid |
| Silicon, shielded | Absorbed dose in silicon behind the selected wall |
Intermediate thicknesses are interpolated in log thickness. Silicon dose is the water dose times the stopping-power ratio: 0.80 for ions, 0.84 for electrons and positrons, 0.90 for photons and about 0.05 for neutrons, silicon containing no hydrogen. Each target is shown by particle type, integrated over the selected duration, and placed on a logarithmic scale of reference doses.
Reference doses
| Used for | Source | Basis |
|---|---|---|
| Banana ≈ 0.1 µSv committed dose (K-40) | this project Conventional ballpark used in radiation-protection outreach, not a measurement | rule of thumb |
| Chest X-ray (PA) 0.02 mSv; chest CT 6.1 mSv | Mettler et al. (2008) | review of measurements |
| NY–LA round-trip flight 0.03 mSv | Bardo & Brown (2008) Table 2 | review |
| US natural background 3.1 mSv/yr | NCRP Report No. 160 (2009) | standard |
| Deep-space GCR inside MSL: 1.84 mSv/day | Zeitlin et al. (2013) | primary measurement |
| US occupational limit 50 mSv/yr TEDE | 10 CFR 20.1201 | regulation |
| NASA career limit 600 mSv effective dose | NASA-STD-3001 Vol. 1 Rev. B (2022) Vol. 1 Rev. B (2022) | standard |
| ARS above ~0.7 Gy acute; LD50/60 ~2.5–5 Gy without treatment | CDC, Acute Radiation Syndrome: Information for Clinicians | guidance |
| Total-ionizing-dose hardness levels M 3 krad(Si) … H 1 Mrad(Si) | MIL-PRF-38535 RHA designators | standard |
| Si/water dose ratios (0.80 ions, 0.84 e±, 0.90 γ, ~0.05 n) | this project Bethe stopping-power ratio (Z/A and I = 75 vs 173 eV); photon μ_en/ρ ratio near 1 MeV; Si neutron kerma vs tissue (order of magnitude) | derived |
Comparison with measurements
- Behind 10 g/cm² at 1 AU the model gives 29.6 mrad(Si)/day; the silicon detector of the Radiation Assessment Detector measured 33.2 mrad(Si)/day in cruise to Mars Zeitlin et al. (2013).
- The corresponding crew value, 1.1 mSv/day, lies below the measured 1.84 mSv/day because it includes 5 g/cm² of body tissue.
- On the Space Station orbit (400 km, 51.6°), absorbed dose in water behind the ISS interior distribution (shielding) is 0.43 mGy/day with the AP-8 solar-minimum belts and 0.32 mGy/day with the solar-maximum belts. Passive dosimeters at 11 locations in the Columbus module measured 0.195 to 0.36 mGy/day Berger et al. (2016). Behind a single 10 g/cm² wall the model gives 0.89 mGy/day: most of the Station's mass lies well beyond 10 g/cm², and trapped protons, which dominate in low Earth orbit, are strongly attenuated by it. The result depends mainly on the thinnest sectors: closing the distribution at 1 or 5 g/cm² instead of 3 gives 0.50 or 0.40 mGy/day at solar minimum.
- The model mean quality factor on the Station is below the measured value Berger et al. (2016), since a point dose omits target fragments produced inside the body.
Expected accuracy of the dose estimates is a factor of 2 to 3 (validation).
Radial dependence of quiet-time dose
Steady solar output (visible light and the 1 keV solar wind) is stopped within the first micrometers of a suit or hull. Quiet-time internal dose is therefore due to galactic cosmic rays, whose intensity increases slowly with heliocentric distance. In the model, extravehicular dose equivalent is about 1.5 mSv/day between 0.1 and 1 AU and about 2.2 mSv/day at 15 AU.
During solar particle events the dependence reverses: inside 1 AU the peak rate scales as r⁻²·⁷, so at 0.11 AU the peak of the October 2003 event is about 400 times its 1 AU value. The dose panel identifies the applicable regime.
Dose against depth (Python engine)
- Method
- SHIELDOSE-2 for electrons, bremsstrahlung and protons.
- Checked against
- Nothing independent yet.
- Expect
- No heavy ions or neutrons, so deep-shielding cosmic-ray dose is underestimated.
The Python engine also provides SHIELDOSE-2 Seltzer (1994) for dose behind aluminum from trapped particles and solar protons, as a function of depth in slab and solid-sphere geometries.